草逼com,亚洲超爽a级毛片,免费真人做受视频在线,久久国产精品久久

客戶榮譽(yù)
kehury
技術(shù)文章
  • 南陽PPC4E Gas Pressure Controller Kits 6241
  • 利用數(shù)字示波器完成視頻信號基本測量
  • 了解WSS溫度計的工作原理及應(yīng)用
  • 安捷倫科技推出mid-bus探頭
  • 電子秤15種常見故障判斷及處理方法
  • 度量衡單位換算表
  • 使用TDS3000系列數(shù)字熒光示波器觀察波形的頻率成分
  • 在線溶解氧(DO)分析儀的測量原理及維護(hù)
  • 熱電偶的結(jié)構(gòu)形式
  • 溫度計、壓力計等怎樣連接計算機(jī),使計算機(jī)按時間記錄溫度、壓力?
  • 當(dāng)前位置:首頁 > 南陽儀器儀表 > 南陽電子電工 > 南陽計量校準(zhǔn)
    PPC4E Gas Pressure Controller Kits
    型 號:6241
    品 牌:美國FLUKE
    技術(shù)指標(biāo):Power requirements
    100 to 240 V ac (-15%, +10%), 50-60 Hz, 70 VA max consumption
    南陽PPC4E Gas Pressure Controller Kits-6241-美國FLUKE

    A simple, complete gas calibration solution

    Fluke Calibration 6241 and 6242 PPC4E gas pressure controller kits feature PPC4E models to cover a very wide workload combined with the accessories needed for a complete calibration system. Included is the Fluke Calibration SPLT self-purging liquid trap to capture moisture in the test line and automatically purge to prevent contamination of the PPC4E, preventing errors and protecting your investment. Also included is interconnect hardware and a test station with a quick connect fitting to mount your pressure device to be tested. 6241 and 6242 kits provide the hardware for a complete gas calibration system.

    ·         Precise pressure measurement and automated control, with ranges available from ± 15 kPa to 14 MPa (± 2.2 psi to 2,000 psi)

    ·         Gauge, absolute and negative gauge (vacuum) modes included on most models

    ·         Switch between absolute, gauge and bidirectional gauge modes and meet easy-to-understand full-year measurement specifications without added hardware or special calibration or maintenance operations

    ·         ± 0.02 % one-year accuracy of any selected Autorange span, with Autorange span as low as 1 % of device full scale. Up to 100:1 accurate ± 0.02 % measure and control range turndown can truly be realized by a single calibrator

    ·         Self-purging liquid trap included to automatically protect PPC4E from system contamination

    ·         AutoTest™, AutoRange, ready/not ready indicator, set point jog feature, real-time measurement uncertainty display, RS-232 and IEEE-488.2 remote interfaces and other advanced features to automate, simplify testing, improve safety and prevent calibration errors and damage to equipment

    ·         Quick connect test stand and interconnect to connect to the device under test

    ·         Standard color graphical user interface with full support in 11 languages

    Outstanding, wide-range performance in a single instrument

    The Fluke Calibration PPC4E is the latest member of our PPC family of controller/ calibrators to deliver extremely broad pressure range coverage at a level of performance that addresses your most common calibration workload. Calibrate transmitters, transducers, pressure switches, indicators, barometers and analog and digital gauges with ease using the color graphical user interface and advanced features.

    PPC4E nominal measurement uncertainty is ± 0.02 % of AutoRanged span. The AutoRange feature allows you to quickly and easily align PPC4E performance to match your requirements exactly. Are you trying to decide if you can provide the best coverage if you buy a 300 psi or a 160 psi calibrator? What if you later need to calibrate a 200 psi device? With PPC4E it doesn’t matter—accuracy is based on any AutoRanged span you enter, as long as it is within the instrument’s turndown range:

    ·         PPC4E models, 10:1 turndown (0.02 % of any AutoRanged span down to 10 % of PPC4E full scale pressure span)

    ·         PPC4EX models, 100:1 turndown (0.02 % of any AutoRanged span down to 1 % of PPC4E full scale pressure span)

    What if you receive a barometer for calibration? …or a vacuum gauge? PPC4E is still the right tool. All models (except for PPC4E 15K) include absolute pressure and negative gauge (vacuum) capabilities. Some PPC4E models also provide excellent coverage of draft pressure (inches of water, mbar) ranges. With multiple pressure modes and very wide turndown capabilities, one PPC4E controller can effectively replace multiple controllers, calibrators or even gas deadweight testers and deadweight ball gauges. Move up to the well-known reliability and precision of a Fluke Calibration PPC4E pressure controller and enjoy great value and return on investment.

    General Specifications

    Warm up time

    None required, 30 minute temperature stabilization recommended for best performance from cold power up

    Resolution

    To 1 ppm, user adjustable

    Power requirements

    100 to 240 V ac (-15%, +10%), 50-60 Hz, 70 VA max consumption

    Operating temperature range

    10 to 40 °C

    Weight

    16.6 kg (36.5 lb)

    Dimensions

    19 cm H x 35 cm W x 45 cm D (7.5 in. x 13.8 in. x 17.7 in.)

    Remote communication interfaces

    RS232 (COM1, COM2), IEEE-488.2, USB (front panel, firmware load only)

    Operating medium

    Any clean, dry, non-corrosive gas

    Pressure connections

    TEST (+), TEST (-):

    1/8 in. NPT F

    SUPPLY:

    1/8 in. NPT F

    EXHAUST:

    3/8 in. NPT F

    ATM:

    10-32 UNF


    PPC4E measurement uncertainty (includes precision and one year stability)1,2

    PPC4EX 14M

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: 140

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.1
    Minimum AutoRanged span [kPa]2: 140

    PPC4E 14M

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: 1400
    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 1
    Minimum AutoRanged span [kPa]2: 1400

    PPC4EX 7M

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: 70

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.05
    Minimum AutoRanged span [kPa]2: 70

    PPC4E 7M

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: 700

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.5
    Minimum AutoRanged span [kPa]2: 700

    PPC4EX 1.4M

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: 14

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.014
    Minimum AutoRanged span [kPa]2: 70

    PPC4E 1.4M

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: 140

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.1
    Minimum AutoRanged span [kPa]2: 140

    PPC4EX 100K

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: ± 1

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.014
    Minimum AutoRanged span [kPa]2:70

    PPC4E 100K

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: ± 10

    Absolute uncertainty1,4
    % of AutoRanged span: 0.02
    Constant [kPa]: 0.014
    Minimum AutoRanged span [kPa]2: 70

    PPC4E 15K

    Gauge uncertainty1,3
    % of AutoRanged span: 0.02
    Minimum AutoRanged span [kPa]2: ± 1.5

    1.     Maximum deviation of the RPT indication from the true value of applied pressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement."

    2.     For AutoRange spans below the Minimum AutoRanged span uncertainty is equal to the value at the Minimum AutoRanged span.

    3.     Gauge uncertainty is a % of AutoRanged span. For example, an AutoRanged span of 3 500 kPa on model PPC4E 7M would have uncertainty of (0.02% * 3 500 kPa) = 0.35 kPa.

    4.     Absolute uncertainty is the sum of a % of AutoRanged span and a Constant that accounts for zero drift. For example, an AutoRanged span of 80 kPa on model PPC4EX 100K would have uncertainty of (0.02% * 80 kPa + 0.014 kPa) = 0.03 kPa.

    On-board barometer

    The on-board barometer is used only to measure changes in atmospheric pressure to provide dynamic compensation of an absolute RPT’s atmospheric pressure offset in gauge measurement mode with PPC4E models other than PPC4E 15k.

    On-board barometer

    Warm up time

    None required

    Range

    70 to 110 kPa (10 to 16 psi)

    Resolution

    0.001 % of span

    Precision
    Predicted stability

    0.1 % of span
    0.05 kPa/yr (0.008 psi/yr)


    Pressure control specifications

    Control precision

    PPC4E:
    ±0.0006% of controller span

    PPC4EX:
    ±0.0006% of controller span (AutoRanged span >10% of controller span)
    ±0.00006% of controller span (AutoRanged span ≤10% of controller span)

    Lowest controllable pressure
    (gauge mode)

    Zero set by automated venting. Lowest point above or below zero limited only by RPT resolution and control precision.

    Lowest controllable pressure
    (absolute, negative gauge modes)

    1 kPa absolute (0.15 psia) or gauge equivalent, for all models except PPC4E 7M and PPC4E 14M

    3.5 kPa(0.5 psia) for PPC4E 7M

    7 kPa(1 psia) for PPC4E 14M

    Ultimate pressure
    (absolute, negative gauge)
    Depending on vacuum pump and connections

    200 to 700 Pa absolute(2 to 7 mbar, 0.03 to 0.1 psia) or gauge equivalent

    Typical pressure setting ready time
    (0.005% hold limit, 50 cc test volume)

    15 to 30 s

    Slew time
    (ATM to FS with 50 cc test volume)

    30 s

    Typical test volume

    0 to 1000 cc for Controller Range of 1.4 MPa
    [300 psi] or less
    0 to 500 cc for Controller Range greater than 1.4 MPa [300 psi]

    Default dynamic control hold limit

    ± 0.01 % of current range

     

    型號

    描述

    6241-15K

    PPC4E Gas Pressure Controller Kit with PPC4E 15K, ± 1.5 to ± 15 kPa (± 0.2 to ± 2.2 psi) 

    Includes:

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    6241-100K

    PPC4E Gas Pressure Controller Kit with PPC4E 100K, ± 10 to ± 100 kPa (± 1.5 to ± 15 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    6241-1.4M

    PPC4E Gas Pressure Controller Kit with PPC4E 1.4M, 140 to 1,400 kpa (20 to 200 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    6241-7M

    PPC4E Gas Pressure Controller Kit with PPC4E 7M, 700 to 7,000 kPa (100 to 1,000 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

    6242-100K

    PPC4E Gas Pressure Controller Kit with PPC4EX 100K, ± 1 to ± 100 kPa (± 0.15 to ± 15 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    6242-1.4M

    PPC4E Gas Pressure Controller Kit with PPC4EX 1.4M, 14 to 1,400 kpa (2 to 200 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    6242-7M

    PPC4E Gas Pressure Controller Kit with PPC4EX 7M, 70 to 7,000 kPa (10 to 1,000 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    6242-14M

    PPC4E Gas Pressure Controller Kit with PPC4EX 14M, 140 to 14,000 kPa (20 to 2,000 psi)

    Includes: 

    ·         PPC4E pressure controller/calibrator with power line cords and operating manual

    ·         SPLT self-purging liquid trap with connector to PPC4E

    ·         Mountable test stand for device under test with interconnect and quick connect fitting with adapters

     

    通用配件:


    配件

    描述

    Case

    加固且可重復(fù)使用的模制裝運(yùn)外殼(部件號 3338097

    機(jī)架安裝套件

    標(biāo)準(zhǔn) 19in 機(jī)架安裝工具機(jī)架

    PK-PPC-BG-DVU

    BG15K Q-RPT 用雙倍容積單元(部件號 3070389

    真空參考套件,220V

    用于 PPC EXHAUST 端口的真空泵套件包括連接器(部件號 3584486

    COMPASS for Pressure

    自動執(zhí)行測試、數(shù)據(jù)采集、報告與設(shè)備資產(chǎn)管理的軟件

    RS232

    9 針線,,2m,用于 PPC4E COM1(部件號 2758335

     

    同類產(chǎn)品
    www.sim-placement.com 南陽PPC4E Gas Pressure Controller Kits 版權(quán)所有 備案號: 魯ICP備08106748號